Grain Size distribution of fine aggregate

Aim
To determine fineness modulus of fine aggregate and classifications based on IS:383-1970

Apparatus
Test Sieves conforming to IS : 460-1962 Specification of 4.75 mm, 2.36 mm, 1.18 mm, 600micron, 300micron, 150 micron, Balance, Gauging Trowel, Stop Watch, etc.

Procedure:
1. The sample shall be brought to an air-dry condition before weighing and sieving. The air-dry sample shall be weighed and sieved successively on the appropriate sieves starting with the largest.

2. Material shall not be forced through the sieve by hand pressure. Lumps of fine material, if present, may be broken by gentle pressure with fingers against the side of the sieve.

3. Light brushing with a fine camel hair brush may be used on the 150-micron and 75-micron IS Sieves to prevent aggregation of powder and blinding of apertures.

4. On completion of sieving, the material retained on each sieve, together with any material cleaned from the mesh, shall be weighed.

Observation :

I S Sieve

Weight
Retained
on Sieve

Percentage of
Weight
Retained (%)

Percentage of
Weight
Passing (%)

Cumulative
Percentage of
Passing (%)

4.75 mm


2.36 mm

1.18 mm

600 micron

300 micron

Total


Result 

----------------------------------------------------------------
Thankyou for the visit
----------------------------------------------------------------

Read more>>>