KMBR 2019 Well and Rainwater harvesting

Setback for Wells and Rainwater harvesting.

  • The set back from any street shall be as that required for a building.
  • There shall be minimum 1.20 metres set back from other boundaries.
  • The well may be located within or abutting or away from the building in the plot
The components of workable groundwater recharging arrangements include:
  • Roof gutters 
  • Down pipe and first flush pipe arrangement
  • Filter unit and 
  • Storage tank with provisions for drawing water and spill over

No leech pit, sock pit, refuse pit, earth closet or septic tank shall be allowed or made
within a distance of 7.5 metres radius from any existing well used for supply of
water for human consumption or domestic purpose or within 1.2 m distance from the
plot boundaries.

Wall and surrounding.— The well shall be protected with brick wall with minimum 1
metre height.

The minimum capacity of the rainwater storage tank

Group A1 ,A2 ,F,J

25 litres/sq.metre of Covered area

Group B,C,D,E, G1 ,G2

50 litres/sq.metre of Covered area

 